Input Voltage:
Input Frequency: Input Current:
Inrush Current: Switching Frequency: Brown Out Voltage: Output Power: Power Up Time: Power Good:
Power Fail:
Efficiency: Altitude: Protection:
Thermal System:
Temperature Coefficient: Temperature:
Humidity: Dimensions:
|
|
90~135VAC, nominal 115VAC (90V at 200W, 103V at 250W load) or 180~265VAC, nominal 230VAC; selectable by side switch 47~63Hz single phase 6A (RMS) for 115VAC at without AC outlet; 3A (RMS) for 230VAC 70A at cold start 30KHz typical 95V~max. 60Hz 250W at 45°C < 20ms for +5V output voltage The power good signal will not be higher than 100~500ms after the +5V output stabilizes at its operating value when the unit is turn on The TTL compatible signal will go down at least 1ms before +5V below 4.75V 80% min. at full load (AC input 230V) 10,000 feet Over Voltage: 5.5~6.9V for +5V output, 13.8~15.6V for +12V output Over Load: Total output from 110% min. to 140% max.; all output equipped w/short circuit protection; the outputs shall shut down if shorted to zero volts output Forced air ventilation by DC ball bearing cooling fan; fan status monitoring is optional +0.05% per°C Operating: 0~50°C Storage: -10~+70°C Operating: 20~90% RH Storage: 10~98% RH 15.0 x 14.0 x 8.6 cm |
|